Platinum Resistance Calculator

Enter three temperature-resistance data sets to fit formula parameters C1, C2, C3

Back to Tools List

Data Input

Calculation Results

IEC 60751 Standard Parameters

R = R0 × (1 + A×t + B×t² + C×(t-100)×t³)

R0 (0℃阻值)1000 Ω
A (= C1×10³)3.9083
B (= C2×10⁷)-5.775
C (= C3×10¹²)-4.183